HCG.HCT.HC Type Pressure Control Valves
Product Name : HCG.HCT.HC Type Pressure Control Valves
Additional files : HCT.pdf
MODLE | MAX.OPERATING PRESSURE kgf/cm 2 | MAX. FLOW l/min | PRESSURE ADJ. RANGE kgf/cm 2 | WEIGHCT kg | ||
---|---|---|---|---|---|---|
THREADED CONNECTIONS | SUB-PLATE MOUNTING | |||||
HCT-03-※ | HCG-03-※ | 250 | 50 |
A : 18-35
B : 35-70 C : 70-140 |
4.3 | 5 |
HCT-06-※ | HCG-06-※ | 125 | 7.6 | 8 | ||
HCT-10-※ | HCG-10-※ | 250 | 15.8 | 14 |
HOW TO ORDER
HC | G | - | 06 | - | A | - | 4 | |||
---|---|---|---|---|---|---|---|---|---|---|
![]() |
1 : INTERNAL PILOT & DRAIN 2 : INTERNAL PILOT EXTERNAL DRAIN 3 : EXTERNAL DRAIN & PILOT 4 : EXTERNAL PILOT INTERNAL DRAIN |
|||||||||
![]() |
PRESSURE ADJUSTING RANGE A : 18-35 kgf/cm 2B : 35-70 kgf/cm 2 C : 70-140 kgf/cm 2 |
|||||||||
![]() |
VALVE SIZE 03 : 3/8” 06 : 3/4” 10 : 1-1/4” |
|||||||||
![]() |
MOUNTING G : SUB-PLATE MOUNTING T : THREADED CONNECTIONS |
|||||||||
![]() |
SERIES NUMBER |
ATTACHMENT
MODLE | SOC HOL CAP SCREW |
---|---|
HCG-03 | M10 x 70L…….4pcs |
HCG-06 | M10 x 80L…….4pcs |
HCG-10 | M10 x 95L…….6pcs |